This page lists the Infranet Controller settings that the security device (Infranet Enforcer) uses.
Infranet Controller Settings
Contact Interval: Specify how often the security device should ping the Infranet Controller for connectivity. The default value is 10 seconds and the range is 3 to 300 seconds.
Timeout Action: Specify what action to take when the Infranet Controller times out:
close removes existing sessions and dynamic configuration and blocks further traffic.
open allows existing and new session traffic as allowed by infranet policies.
no-change preserves existing connections and dynamic configuration, such as tunnels, but new sessions require authentication.
Infranet Enforcer Settings
Mode: Select Regular (default) or Test only.
Test only places the security device in test mode, where traffic is always allowed and policies are not enforced. However, the permit or deny decision associated with the infranet-auth policies is logged.
Regular turns off the “test” mode. The infranet-auth policy decisions are enforced and not only logged. In this default mode, the infranet-auth policies are applied and logged based on the auth table entries.